Removing the Under-Voltage rainbow warning

The B+ has an under voltage detect trigger which results in the power led going off when voltage drops below about 4.65V. The signal is also available on a gpio line (GPIO35). Latest firmware update will display a warning symbol in top right of display when this is detected. It will also disable turbo mode…